System One BiPAP Ventilatory support system

System One BiPAP AutoSV Advanced

Ventilatory support system

Surasti panašius produktus

Easily and efficiently treat your most complicated sleep-disordered breathing (SDB) patients.

Features
Real-time access

Real-time access for improved compliance and efficacy

The system helps you assess the success of treatment by granting improved real-time access to a patient’s data. Access daily patient usage, compliance and efficacy data.
Bi-Flex technology

Bi-Flex technology enhances patient comfort

Bi-Flex pressure relief technology makes BiPAP therapy more like natural breathing by delivering pressure relief at three critical points in the breathing cycle.
Clinically proven algorithms

Clinically proven algorithms monitor treatment.

Continually monitor and adjust to a patient's changing therapy needs with clinically proven algorithms, including the innovative EPAP.
Encore Anywhere

Encore Anywhere simplifies patient management

This state-of-the-art data management and reporting system automatically gathers vital patient information.
Servo Ventilation

Servo Ventilation normalizes unstable breathing

This algorithm monitors peak flow and changes pressure support breath by breath to stabilize the breathing pattern.
Humidity control technology

Humidity control technology for enhanced, comfortable therapy

Integrates with System One heated humidifier. The system analyzes ambient temperature, relative humidity and patient flow, for enhanced comfort and compliance.
  • Real-time access
  • Bi-Flex technology
  • Clinically proven algorithms
  • Encore Anywhere
See all features
Real-time access

Real-time access for improved compliance and efficacy

The system helps you assess the success of treatment by granting improved real-time access to a patient’s data. Access daily patient usage, compliance and efficacy data.
Bi-Flex technology

Bi-Flex technology enhances patient comfort

Bi-Flex pressure relief technology makes BiPAP therapy more like natural breathing by delivering pressure relief at three critical points in the breathing cycle.
Clinically proven algorithms

Clinically proven algorithms monitor treatment.

Continually monitor and adjust to a patient's changing therapy needs with clinically proven algorithms, including the innovative EPAP.
Encore Anywhere

Encore Anywhere simplifies patient management

This state-of-the-art data management and reporting system automatically gathers vital patient information.
Servo Ventilation

Servo Ventilation normalizes unstable breathing

This algorithm monitors peak flow and changes pressure support breath by breath to stabilize the breathing pattern.
Humidity control technology

Humidity control technology for enhanced, comfortable therapy

Integrates with System One heated humidifier. The system analyzes ambient temperature, relative humidity and patient flow, for enhanced comfort and compliance.
Do you want to know what it means when products are certified for European Union Medical Device Regulations (EU MDR)?

Specifikacijos

General system
General system
Filters
  • Foam and optional ultra-fine
Altitude compensation
  • Automatic
Electrical requirements
  • 100-240 VAC and 50/60 Hz
On-board data storage capacity (minimum)
  • up to 6 months
Flex pressure relief
  • Bi-Flex
Data storage capacity Display (minimum)
  • Compliance VIC 7- and 30-day averages
Data storage capacity SD Card (minimum)
  • >1 year(s)
Device set-up
  • LCD/control wheel/push button
Pressure Range
  • 4 to 25 (EPAP) and 4 to 25 (IPAP) cm H₂O
Compliance meter
  • Breathing detection
Warranty
  • Two years; replace with new
Miscellaneous
  • Lighted LEDs
Humidification
  • Integrates with System One heated humidifier
Dimensions without humidifier
  • 18 cm L x 14 cm W x 10 cm H (7" L x 5.5" W x 4" H)
Weight without humidifier
  • 1.53 (3.37) kg (lbs)
Ramp time
  • 0 to 45 (5-min. increments) minute(s)
Starting ramp pressure
  • 4 to EPAP (patient-adjustable) cm H₂O
General system
General system
Filters
  • Foam and optional ultra-fine
Altitude compensation
  • Automatic
See all specifications
General system
General system
Filters
  • Foam and optional ultra-fine
Altitude compensation
  • Automatic
Electrical requirements
  • 100-240 VAC and 50/60 Hz
On-board data storage capacity (minimum)
  • up to 6 months
Flex pressure relief
  • Bi-Flex
Data storage capacity Display (minimum)
  • Compliance VIC 7- and 30-day averages
Data storage capacity SD Card (minimum)
  • >1 year(s)
Device set-up
  • LCD/control wheel/push button
Pressure Range
  • 4 to 25 (EPAP) and 4 to 25 (IPAP) cm H₂O
Compliance meter
  • Breathing detection
Warranty
  • Two years; replace with new
Miscellaneous
  • Lighted LEDs
Humidification
  • Integrates with System One heated humidifier
Dimensions without humidifier
  • 18 cm L x 14 cm W x 10 cm H (7" L x 5.5" W x 4" H)
Weight without humidifier
  • 1.53 (3.37) kg (lbs)
Ramp time
  • 0 to 45 (5-min. increments) minute(s)
Starting ramp pressure
  • 4 to EPAP (patient-adjustable) cm H₂O